CHARMO 19 Inverter Heat Pump W/24kBTU 208/1/60 ODU
Description
| SPECIFICATIONS GWH24QE-D3DND6L/I | |
| System Type | HEAT PUMP |
| SYSTEM PERFORMANCE | |
| Min – Max | 6824 – 25249 Btu/h |
| Cooling | |
| Min – Max | 5971 – 27296 Btu/h |
| Capacity @95°F | 22000 Btu/h |
| Capacity @5°F | Btu/h |
| Heating | |
| Capacity @17’F | 13900 Btu/h |
| Capacity @47°F | 24000 W |
| SEER2 | 18.0 |
| EER2 | 11.6 |
| HSPF/HSPF2 | 10/8.5 |
| COP @5°F | |
| COP @47°F | 3.4 |
| Cooling Temperature Range | 0 – 122 °F |
| Heating Temperature Range | -13 – 75 °F |
| Refrigerant Type | R410A |
| INDOOR UNIT GWH24QE-D3DND6L/I | |
| Air flow (Min-Max) | 412-677 CFM |
| Sound Pressure Level (Min – Max) | 36 – 51 dB(A) |
| Dehumidification | 5.28 pt/hr |
| External Dimensions (WxHxD) | 42-7/16 x 13-1/8 x 9-11/16 in |
| Package Dimension (WxHxD) | 44-5/8 x 16-5/16 x 13-1/8 in |
| Net Weight | 33.1 lbs |
| Gross Weight | 39.7 lbs |
| OUTDOOR UNIT GWH24YE-D3DNA1A/O | |
| Compressor Type | GREE G-10 / 2-STAGE INVERTER |
| Sound Pressure Level | 57 dB(A) |
| External Dimensions (W x H x D) | 37-3/4 x 26 x 15-7/8 in |
| Package Dimension (WxHxD) | 40-5/8 x 29-1/16 x 17-15/16 in |
| Net Weight | 97 lbs |
| Gross Weight | 106.9 lbs |
| REFRIGERANT PIPING | |
| Refrigerant Charge – R410A | 52.9 OZ |
| Additional Charge | 0.5 oz/ft |
| Line Set Size (Liquid – Gas) – Flared Connections | 1/4-5/8 in |
| Pre-Charge Length | 25 ft |
| Pipe Length (Min – Max) | 10 – 82 ft |
| Max. Pipe Elevation | 33 ft |
| ELECTRICAL | |
| Power Supply | 208-230V/1Ph/60Hz |
| Voltage Range (Min – Max) | 187 – 253 VAC |
| Rated Current – Cooling | 12 A |
| Rated Current – Heating | 12 A |
| MCA | 15A |
| MOCP | 20 A |
| Suggested Breaker Size | 15 A |
| Main Power Wire Size | Per Local Code AWG |
| Interconnecting Wire Size | 14/4 AWG |